Q-tech QT802 Square Wave Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 10
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
QT801 and QT802 Square-Wave
24 pin DDIP
REV.
Q-TECH Corporation
10150 W. Jefferson Blvd.
Culver City, CA 90232
SIZE
A
CAGE NO.
51774
Sheet 6 of 10
D
Group C Inspection
SUB-
GROUP
TEST
DESCRIPTION
CONDITION
QTY
Vibration (random)
MI-STD 202 Method 214/ T.C. I-K (46Grms) for 3 minutes in
each plane.
Shock
MI-STD 202 Method 213 T.C. F
(1500g, 0.5ms half-sine pulse) 3 blows each direction of three
axes (18 shocks total)
Electrical Test
Frequency, Output levels, Input Current
@ +25°C & Temp Extremes listed on the Electrical
Specification.
Hermetic Seal
Fine Leak MIL-STD-883 Method 1014 Condition A1
Gross Leak MIL-STD-883, Method 1014 Condition C
Electrical Test
Frequency, Output levels, Input Current
@ +25°C & Temp Extremes listed on the Electrical
Specification.
Temperature
Cycling
MI-STD 883, Method 1010, TC B 100 cycles.
Electrical Test
Frequency, Output levels, Input Current
@ +25°C & Temp Extremes listed on the Electrical
Specification
Ambient Pressure
(Non-Operating
2 MI-STD 202 Method 105 T.C. C
Electrical Test
Frequency, Output levels, Input Current
@ +25°C & Temp Extremes listed on the Electrical
Specification
Storage
Temperature
Low Temp.of - 55 (+0, -5) °C
HighTemp.of +150 (+5,-0) °C
Hermetic Seal
Fine Leak MIL-STD-883 Method 1014 Condition A1
Gross Leak MIL-STD-883, Method 1014 Condition C
1
Electrical Test
Frequency, Output levels, Input Current @ +25°C & Temp
Extremes listed on the Electrical Specification
4 parts
(0 failures)
Resistance to
Soldering Heat
MI-STD 202 Method 210 T.C. B
Hermetic Seal
Fine Leak MIL-STD-883, Method 1014 Condition A1
Gross Leak MIL-STD-883, Method 1014 Condition C
3
Moisture
Resistance
MI-STD 202 Method 106
1 parts
(0 failures)
Terminal Strength
(Lead Integrity)
MI-STD 202 Method 211 T.C. B
Visual Inspection
Hermetic Seal
Fine Leak MIL-STD-883,Method 1014 Condition A1
Gross Leak MIL-STD-883, Method 1014 Condition C
4
Resistance To
Solvents
MI-STD 202 Method 215
1 parts
(0 failures)
NOTE: Samples from Su/jointfilesconvert/1386194/bgroup 1 may be divided and used for Su/jointfilesconvert/1386194/bgroups 2, 3, and 4 Inspections.
ITAR-CONTROLLED Q-TECH PROPRIETARY DO NOT COPY OR DISTRIBUTE WITHOUT Q-TECH APPROVAL
Seitenansicht 5
1 2 3 4 5 6 7 8 9 10

Kommentare zu diesen Handbüchern

Keine Kommentare